LAMINAR FLOW SYSTEM · ISO 5

Laminar Flow System

The laminar flow system creates a highly clean, contamination-controlled environment for sensitive processes. By producing a uniform, stable, turbulence-free airflow it removes airborne particles, microbial contamination and environmental pollutants from the work zone.

KGS laminar flow system with clear PVC curtains and locking castors
ISO 5cleanliness class in the work zone
0.3 – 0.5 m/sstandard airflow velocity range
HEPA ≥ 99.97%efficiency for 0.5 µm particles

Operating principle

Room air passes through a pre-filter that removes coarse particles, then through the final filtration stage: HEPA filters with at least 99.97% efficiency for 0.5 µm particles. The fully filtered air is distributed across the work zone at a uniform, controlled velocity. Engineered airflow paths and careful selection of a high-efficiency fan achieve the standard velocity of about 0.3 to 0.5 m/s and cleanliness up to ISO Class 5 in the work zone.

Construction features

Body

Durable and washable

The structure is made of durable, washable materials and the work surface of hygienic stainless steel, making cleaning and disinfection easy.

Lighting and UV

Good visibility and sterilisation

Lighting at standard intensity, with an optional ultraviolet (UV) lamp to sterilise the work area before operation.

PVC curtains

Semi-isolated work zone

Clear antibacterial PVC curtains around the work area keep out particles and micro-organisms while preserving the laminar flow field and easy operator access.

Applications

Precise air-distribution design, uniform flow, low noise, high reliability and quality filters make the system suitable for:

  • Pharmaceutical industry
  • Medical Devices
  • Microbiology laboratories
  • Sterile processes
  • Assembly lines for sensitive components
  • Other applications that require contamination control